AI Analog Input
  • AI Analog Input
  • AI Analog Input
  • AI Analog Input
  • AI Analog Input
  • AI Analog Input

Professional Modules ADC01 is an industrial analog input module with Modbus.

Price Price range: ¥78.00 through ¥98.00
SKU: OS-LIVE-59AC7A95F62844B8BAEDB5C37C3A5845-EN Categories: ,
AI Analog Input

⚡ Why choose AI Analog Input?

LTCN ADC01 is an industrial analog input module with Modbus.

Multi-Signal Input

Supports 4-20mA, 0-5V, 0-10V inputs.

Range Conversion

Converts raw AD values to engineering units, supporting direct and inverse output for clear display.

High-Precision Capture

Uses 12-bit ADC resolution with 4096-level precision for stable, accurate data collection.

Strong Anti-Interference

Features ±15KV ESD protection and 600W lightning surge protection for harsh industrial environments.

Modbus Communication

Standard RS485 Modbus RTU protocol, supporting 03/06/16 function codes for PLC and industrial instrument integration.

HA Integration

Built-in Wi-Fi for Home Assistant, ESPHome, and MQTT.

Web Config

Web UI for calibration, MQTT, and theme settings.

📍 Applications

PLC Data Acquisition

PLC Data Acquisition

In industrial automation production lines, connect to the PLC via RS485 to collect and monitor analog data in real time.

HA Environment

HA Environment

Wireless monitoring of environmental sensors via Home Assistant.

Soil Data

Soil Data

Converts soil or water sensor analog signals to digital data.

Device Status

Device Status

Real-time voltage and current monitoring for equipment status.

📊 Product specifications

Product on white background · AI Analog Input
Parameter Specification
Product Name Analog AI Module
Model ADC01
Brand LTCN
Supply Voltage DC 12-24V
Input Voltage/Current DC 12-24V
Interface Type/Qty RS485
Protocol/Band/Rate Standard Modbus RTU
Dimensions 40 × 40 × 22 mm
Weight 100 g
Operating Temp -40 ~ 80℃
Package List AI Module ADC01 x 1

🏠 HA integration · Five steps to Home Assistant

Connect to Home Assistant over Wi-Fi to manage device entities and automations.

1

Connect Wi-Fi and power

The HA version includes Wi-Fi and creates an access point when powered on. Connect a phone or computer to the device hotspot beginning with HA (password: 12345678).

2

Configure the device network

After connecting to the HA-xxxx hotspot, the setup page opens automatically. If it does not, open 192.168.4.1 in a browser. Connect the device to the 2.4 GHz network used by the HA host.

3

Discover the device in HA

Open the devices and management page in Home Assistant. Find the automatically discovered device under the ESP integration and select Configure to add it. Device entities are created automatically, without manually writing configuration.

4

Create automation scenes

Add device entity cards to the HA dashboard and create automations and scene interactions as needed.

5

Reset the device

If the device cannot reconnect to its configured network for about two to three minutes, it resets automatically. You can also select RESET in the HA interface.

HA 配置界面

HA 配置界面

本模块 IP:88 端口网页免系统访问控制截图

本模块 IP:88 端口网页免系统访问控制截图

🔌 Wiring

Label Function
V Power
GND Power
A Analog Comms
B Analog Comms
G Analog Comms
AI Analog Comms

📡 Communication protocol · Communication protocol

Uses Modbus RTU. Defaults: 9600, 8, N, 1. CRC16 low byte first. Supports 03H, 06H, 10H. Floats use ABCD.

**Register address table:**

Register Content Type Access Note
0x0000 Raw data UINT16 Read-only 0-5000 / 0-10000 / 4000-20000
0x0001 Temp value UINT16 Read-only Module Temp (°C)
0x0002~0x0003 Range Scale Float32 Read-only Scaled Value (Read/100=Actual)
0x0004 Device Addr UINT16 R/W 1-247, def 1
0x0005 Baud Rate UINT16 R/W 12=1200, 24=2400, 48=4800, 96=9600, 192=19200…
0x0008~0x0009 Range Upper Float32 R/W Format ABCD, MSB first
0x000A~0x000B Range Lower Float32 R/W Format ABCD, MSB first
0x000C ADC Raw Data UINT16 Read-only 0-4095 Raw AD
0x001D Module restart UINT16 Write-only Restart on non-0 write
Read raw dataRequest: 01 03 00 00 00 01 84 0A
Response: 01 03 02 13 88 B4 0E
Explanation: 0x1388=5000
Read range valueRequest: 01 03 00 02 00 02 65 CB
Response: 01 03 04 42 48 00 00...
Explanation: Convert 0x42480000 to 50.0
Set address to 2Request: 01 06 00 04 00 02 08 0B

Data value notes

  • Defaults: 9600, 8, N, 1
  • CRC16 low byte first
  • Supports 03H (read), 06H (write single), 10H (write multiple)
  • Float format: ABCD (high byte first)

Download manual

Version

Standard, ADC01-0-5V, ADC01-0-10V, HA-ADC01-4-20MA, HA-ADC01-0-5V, HA-ADC01-0-10V

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

laitecn@gmail.com

QQ
微信
Whatapp

HAIOTS